Pura Quick Change 50 Gpd Reverse Osmosis High Performance Drinking Water System Qcro4v-50 Reviews

Quick Links

Installation, Operation & Service Instructions with Function List

Quick Change Reverse Osmosis Drinking Water Organization

Model No. QCRO4V-50

www.pura.com

This system certified by WQA

co-ordinate to NSF/ANSI 58 for

TDS reduction, as verified and

substantiated by test data.

loading

  Also See for Pura QCRO4V-l

Pura QCRO4V-50-PL Operating/Service Instructions Manual

  Summary of Contents for Pura QCRO4V-50

  • Page 1 Installation, Operation & Service Instructions with Office List Quick Change Reverse Osmosis Drinking Water System Model No. QCRO4V-l This system certified past WQA co-ordinate to NSF/ANSI 58 for www.pura.com TDS reduction, every bit verified and substantiated by examination data.
  • Page 2 Massachusetts. The PURA Quick Change Drinking Water System contains a replaceable reverse osmosis membrane filter which is critical for the effective reduction of Total Dissolved Solids. The filtered h2o should be tested periodically to verify that the system is performing properly.
  • Folio 3: Table Of Contents

    Overview of the PURA Quick Change RO System'southward Components ....... .
  • Page 4: Specifications And Functioning Data Sheet

    (Stage iii) ....Thin Film Composite Production Rate 1 ... . . QCRO4V-50 36.5 gpd (138 50/day)
  • Folio v: Performance Data Canvas

    (1) Pressure Regulator is recommended for feed water pressures exceeding 552 kPa (eighty psig). Performance Information Sheet Contaminant Reduction table: Model QCRO4V-50 This system has been tested according to WQA S-300 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the organization, as specified in NSF/ANSI 58.
  • Folio vi: Suggested Installation Equipment

    Suggested Installation Equipment          Recommended tools i. Utility Knife  2. Flathead Screwdriver  3. Phillips Screwdriver  4. Eye Punch 5. 7/8" Stepped Drill Bit vi. Terminate Pigsty Saw 7. Porcelain Saw 8.
  • Page 7: Overview Of The Pura Quick Change Ro Arrangement'south Components

    Dispenser Faucet The PURA faucet (eight) allows the production h2o to exist fatigued from the system with a simple rotation of the handle. This air gap way faucet prevents the unit from siphoning bleed water back into the organisation. It features a built-in siphon interruption for concentrate discharge as required by nigh plumbing codes.
  • Page viii: Parcel Contents

    Package Contents Main Carton        Carton 2 Carton iii               Figure 3 one. RO Manifold with Menstruum Command 9. Bleed Saddle 17.
  • Folio nine: Preparation

    Product Information This manual covers the technical aspects of PURA Quick Alter drinking water systems. It is important to read this transmission thoroughly so that you tin can properly utilize, install, and service these systems. The substances reduced past this system are not necessarily in the customer's untreated water.
  • Page ten Verify Flow Command Location Flow Restrictor The RO manifold comes attached with the elbow fitting flow control. This flow control is fastened to the manifold past quick disconnect plumbing fixtures which allows it to exist hands inverse. Verify it is properly located in the outlet side by side to the symbol.
  • Folio 11: Installation

    (figure 7) must exist observed. The PURA drinking h2o system is designed to be mounted near a sink for easy access to common cold water and bleed lines. Lengths of ane/4-inch and 3/8-inch OD plastic tubing will exist required to brand this installation.
  • Folio 12: Pace 1 Select Component Installation Locations

    The following steps volition enable you to install the system quickly and orderly. Some variation may exist necessary depending on the installation. See page iv for a check list of tools and materials. typical installations follow this sequence: 1. Select Component Installation Locations 2.
  • Page 13: Step 2 Faucet Installation

    Step 2 – Faucet installation To simplify its access and installation, nosotros suggest yous install the faucet on the rear lip of the sink. It should be evenly positioned with the sink faucet and spray attachment. Should the spray faucet hole not be available for the installation, the sink must exist drilled.
  • Folio xiv 3/8" Orange 1/4" Orange Tubing Tubing  Faucet  Base  O-ring (in base) Spacer  (Optional)  Divide Washer  Flat Washer  Lock Washer   Faucet Adapter Drain Line from Faucet (3/8" Orange Tubing) Production Line from RO Manifold (3/viii"...
  • Page fifteen Faucet assembly Verify faucet body, metal base, and rubber base washer are in place above sink (Items 1, 3, and 2). Lower faucet into mounting hole and place faucet over hole. Install slotted washer, spacer, faucet washer, and nut onto faucet nipple beneath sink and snug them up (Items 4, 5, six, 7 and 8).
  • Page 16: Step 3 Install Adapter Valve On Water Supply

    Step iii – install adapter Valve on Water Supply CautioN! The Adapter valve should be connected to cold water supply only. Connection to hot water supply volition harm the system and volition void all warranty Adapter Before installing the adapter valve onto the supply line, in- stall the adapter every bit needed.
  • Page 17: Step 5 Install Reservoir Tank

        Figure 14 one. Install the drain saddle two. Tighten the clamps with 3. Drill 3/8" hole through one 4. Attach 3/8" orange tube by valve on to the drain pipe. the help of the two bolts. side of the pipe.
  • Page 18: Step 6 Install Filter System Assembly

    Step 6 – install Filter Organization assembly The mounting bracket contains four mounting slots. The holes are sized to have #x round head wood screws (supplied). Some types of surfaces such as particle board or drywall, may crave the use of plastic screw anchors or toggle bolts to provide acceptable support for the unit.
  • Page xix: Step seven Outset Up

       Orange Attach locking clips to each white Connect the one/4" OD orange Connect the 3/eight" OD white elbow plumbing fixtures. Exercise not attach one to tubing from the air gap inlet of the product water tube from the tank the blue menstruum control.
  • Page 20: Performance And Technical Information

    Performance & Technical Information The performance of the PURA system can be characterized and judged by the quality and quantity of the water produced past the organization. By measuring the contaminant removal performance and menstruation rates of the system, its operating status tin can be easily evaluated.
  • Page 21: Installing An Ro To Service Other Water Using Appliances

    80, then the total pressure level in the storage tank will be around 53 psi. Increasing the overall pressure in the arrangement volition let more volume to be drawn from the tank before the pressure dips below a shutoff value. Pura Faucet 3/eight" Drain Line...
  • Page 22: Service And Maintenance

    Service Schedule To proceed the PURA system operating properly, it is necessary to change the filters and sanitize the organization periodically. Typically, this should be done on an annual ground. Service frequency may vary depending on local h2o conditions. High sediment, chlorine, turbidity, or hardness levels may require more than frequent service.
  • Page 23: Parts Breakdown

    Parts Breakdown            item # Description Qty. 134040R Manifold, Quick Change RO, four Phase 92223 Valve, Auto Shut-off 41407553 Plumbing fixtures, Bank check Valve, QCRO 41407552 Fitting, T-Connector, QCRO 41407001 Cartridge, Quick Change Sediment Filter - Stage i 41407002 Cartridge, Quick Change Carbon Cake - Stage two &...
  • Page 24 Other Parts   1. Storage Tank – Part # 92371 two. Faucet & Hardware – Part # 92653 3. Drain Saddle – Part # 92160 4. Tank Shut-off Valve – Function # PPSV501222W 5. Adapter Valve ASVPP5 6. 2x Locking Clip (3/8") – Function # 92346 seven.
  • Page 25: Troubleshooting

    Troubleshooting Guide If a problem cannot be corrected through the use of this troubleshooting guide please have the following information ready prior to calling the one-800 number on the dorsum of this manual: • Serial # • Model # Problem Possible Cause Remedy Bereft...
  • Page 26 Problem Possible Cause Remedy External leakage. a. Tubing not fully seated in plumbing fixtures a. Check all fittings for tightness. b. Tubing abraded in seal surface area. b. Recut tubing and redo connectedness. Overflow at a. Concentrate tubing plugged. a. Make clean concentrate tubing of droppings. faucet air gap b.
  • Page 27: Warranty Information

    PURA Guarantee Subject to the weather and limitations described below, WaterGroup warrants its PURA Reverse Osmosis Drinking Water Treatment Systems (excluding membrane and cartridge filters), when installed in accordance with WaterGroup specifications, to be free from defects in materials and workmanship under normal utilize inside the operating specifications for a catamenia of 3 (3) years from the date of buy (with bill of auction).
  • Page 28 WaterGroup Companies Inc. 580 Park Street Regina, SK, S4N 5A9, Canada USA Part: WaterGroup Companies Inc. 193 Osborne Road Fridley, MN, 55432, USA world wide web.pura.com 55014CA.0313...

carltonwhoine1999.blogspot.com